When the diagnostics have been completed and the results uploaded the diagnostics application doesn't get uninstalled and the workflow/process doesn't progress to the next step.
This problem should only occur when "Legacy" diagnostics application is used.
Cause
The cause for this behaviour behavior is the introduction of our a separate screen damage test into the default test sets and all custom test set's in which all tests are selected.
There is a separate diagnostics application installed for this purpose named "Auto Capture".
Resolution
There are two ways in which to resolve this issue as detailed below.
- Manually run the separate "Auto Capture" application which will perform the screen damage test and once completed the result will be uploaded to the computer running the Mobile Diagnostic and Erasure software and the process will continue.
- Remove the Screen damage test from the test sets being used which will
...
- prevent this issue from happening. You can remove the screen damage test by following the steps detailed below.
Panel |
---|
|