If the following settings are configured, the erasure will start and 次の設定が構成されている場合には、Blancco Drive Eraser/Blancco 5 will not attempt the Freeze Lock Removal (は、消去が開始されてもフリーズロック解除(Freeze Lock Removal: FLR) procedure)処理を試行しません:


Setup to avoid the FLR procedureFLR処理を回避する設定:

  1. Load the Drive Eraser Configuration ToolでBlancco Drive Eraser/Blancco 5 ISO image on the Drive Eraser Configuration Tool
  2. Open the “Security” tab *
  3. ISOイメージをロードします。
  4. 「セキュリティ」タブをクリックします。 *
    • Select an erasure method that does not enforce any firmware based erasure (only normal overwriting is allowed).
    • The description of the erasure methods is located in the appendices of the
    • ファームウェアベースの消去を強制しない消去方式を選択します(通常の上書きのみが強制しません)。
      • 消去方式の説明は
      • Blancco Drive Eraser/Blancco 5
    • user manual.
    • Disable “Remove Hidden Areas” option.
    • Disable “Erase Remapped Sectors” option.
    • Disable “Enforce Blancco SSD Method On SSDs” option.
  5. Open the “OS” tab
    • Ensure that the “Boot options” dropdown list is set with any value other than “FLR during startup”.
      • ユーザーマニュアルの付録に記載されています
    • 「隠し領域を解除」オプションを無効化します。
    • 「リマップセクターのデータを消去」オプションを無効化します。
    • SSDBlancco SSD 消去方式を強制」を無効化します。
  6. OS(オペレーティングシステム)」タブをクリックします。
    • 「起動オプション」のドロップダウンリストのが「FLR during startup 以外に設定されていることを確認します。
  7. Save Blancco Drive Eraser/Blancco 5 image

With these settings, the FLR procedure will be entirely skipped at boot time and will not be attempted before or during the erasure.

Any existing freeze lock(s) will remain on the drive(s):

  • As long as the selected erasure settings are not changed, the erasure process will work without a glitch.
  • Selecting other erasure settings (e.g. using the standards “Blancco SSD Erasure” or “NIST 800-88 Purge” or enabling “Erase Remapped Sectors” on a drive having remapped sectors) may trigger the FLR procedure.

Setup to disable the FLR procedure **:

  1. Load Blancco Drive Eraser ISO image on the Drive Eraser Configuration Tool
  2. Open the “OS” tab
    • In the “Booting options” dropdown list, select the value “Customized startup”.
    • On the new fields that appear below the dropdown list, select the “flr” checkbox.
    • On the dropdown list that appears to the right, select the value “disabled”.
  3. Save Blancco Drive Eraser / Blancco 5 image

With these settings, the FLR procedure will be entirely disabled and will not be attempted under any circumstance.

Any existing freeze lock(s) will remain on the drive(s):

  • Most erasure standards (doing normal overwrite) will work without a glitch.
  • Some erasure standards/options that require firmware-based erasure commands (e.g. “Blancco SSD Erasure” or “NIST 800-88 Purge” or enabling “Erase Remapped Sectors” on a drive having remapped sectors) will consistently produce failures on those drives.

Check Blancco Drive Eraser / Blancco 5 Configuration Tool user manual for more information on the different erasure standards and booting options.

* Note that all these settings (“Erasure Standard”, “Remove Hidden Areas”, “Erase Remapped Sectors” and “Enforce Blancco SSD Method On SSDs”) can be accessed directly from the Blancco Drive Eraser / Blancco 5 user interface (Erasure-step > Advanced-view > Erasure options) starting with version 5.10.0.

  1. 5のイメージを保存します。

この設定により、起動時のFLR処理は完全にスキップされ、また消去開始前、あるいは消去中に試行されることもありません。

既存のフリーズロックはすべてドライブに残ります:

  • 選択した消去の設定が変更されない限り、消去処理は問題なく動作します。
  • 他の消去設定を選択すると、FLR処理を引き起こす可能性があります(例:「Blancco SSD Erasure 」または「 NIST 800-88 Purge 」規格を使用する、またはリマップセクターのあるドライブで「リマップセクターのデータを消去」を有効化する)。

FLR処理を無効化する設定 **:

  1. Drive Eraser Configuration ToolでBlancco Drive Eraser/Blancco 5ISOイメージをロードします。
  2. 「OS(オペレーティングシステム)」タブをクリックします。
    • 「起動オプション」のドロップダウンリストで「Customized startup」を選択します。
    • ドロップダウンリストの下に表示された新規のフィールドで、「flr」チェックボックスを選択します。
    • 右側に表示されるドロップダウンリストで「無効」を選択します。
  3. Blancco Drive Eraser/Blancco 5のイメージを保存します。

この設定により、FLRの処理は完全に無効化され、どのような状況でも試行されません。

既存のフリーズロックはすべてドライブに残ります:

  • 通常の上書きを行うほとんどの消去規格は問題なく動作します。
  • ファームウェアベースの消去コマンドを必要とするいくつかの消去規格/オプション(例 :「Blancco SSD Erasure」または「NIST 800-88 Purge」、あるいはリマップセクターのあるドライブで「リマップセクターのデータを消去」を有効化する)は常に失敗を引き起こします。


各種の消去規格と起動オプションの詳細については、Blancco Drive Eraser/Blancco 5 Configuration Tool ユーザーマニュアルを確認してください。


* これらのすべての設定(「消去規格」、「隠し領域を解除」、「リマップセクターのデータを消去」、「SSDBlancco SSD 消去方式を強制」)はバージョン5.10.0以降のバージョンから、Blancco Drive Eraser/Blancco 5UIから直接アクセスすることが可能なことに注意してください。

消去画面 > 詳細表示 > 消去オプション

** ** Requires Blancco Drive Eraser 6.3.0 or higher and Blancco 0以降、Blancco Drive Eraser Configuration Tool 2.3.0 or higher.0以降のバージョンが必要です。