新機能:

  • ALBUS-6997, ALBUS-7005, ALBUS-7006, ALBUS-7007, ALBUS-7260, ALBUS-7299, ALBUS-7300, ALBUS-7301, ALBUS-7302, ALBUS-7303, ALBUS-7304, ALBUS-7305, ALBUS-7576, ALBUS-7577, ALBUS-7578, ALBUS-7579, ALBUS-7878, ALBUST-733 - BDE 6.x, BDECT 2.xとの機能等価性。
  • ALBUS-7318, ALBUS-7573, ALBUS-7577, ALBUS-7576, ALBUS-7303, ALBUS-7302, ALBUS-7299, ALBUS-7260, ALBUS-7007, ALBUS-6997 - 新ユーザーインターフェイス。
  • ALBUS-6428, ALBUST-735 - BDECTで消去設定にロックをかける機能。
  • ALBUS-7970 - AMSとの統合も可能なIBRワークフロー。
  • ALBUS-8496, ALBUST-873 - BDEワークフローをBMCからリモートで実行する機能。
  • ALBUS-8081 - Enterprise Subscriptionエディションの改善。
  • ALBUS-6593 - リマップセクター消去の改善。
  • ALBUS-8095, ALBUST-880 - 事前定義済みカスタムフィールドをIBRワークフロー実行時に保持。
  • ALBUS-6729 - ATAドライブが許容動作温度を超える場合の警告。
  • ALBUS-8243 - ワークフローモードでのカスタムフィールド入力対象ドライブの強調。
  • ALBUS-8486 - TCG OpalのシャドウMBR検出。
  • ALBUST-427, ALBUS-8663 - BDE起動パラメータの自由編集。


改善、バグ修正:

  • ALBUS-8498 - ハードウェアサポート改善のための新カーネル。
  • ALBUS-8550 - バージョン6.18.0に追加されたリモート消去関連機能の移植。
  • ALBUS-8468 - ドライブ別の消去処理用の新アイコン。
  • ALBUS-8422, ALBUS-8280, ALBUS-8546 - QuestionアクションとMessageアクションの改善。
  • ALBUS-8285 - 新カーネル (ALBUS-8498) によるMS Surfaceシリーズのハードウェアサポート状況改善。
  • ALBUS-8555 - バージョン6.17.0で発生したカスタム電子署名の不具合を修正。
  • ALBUS-8587 - Dell ITPACサーバー (Intel Patsburg-J コントローラをもつDell DCS7220N) が起動しない。
  • ALBUS-8551, ALBUS-8448 - ファームウェアベースの消去規格がサポート対象外と表示される不具合を修正。
  • ALBUS-8556 - ATAセキュリティ機能のみ有効状態のATAドライブの検出と処理の改善。
  • ALBUS-8554 - Fixing detection and erasure speed problems for large drives behind Adaptec SmartIOC 8i controllers.
  • ALBUS-8447 - Fixing the detection of the capacity of LITEON IT L8H-64V2G 64 GB SATA/SSD.
  • ALBUS-8093, ALBUS-7873, ALBUS-7824, ALBUS-8695 - Fixing booting issues (Asus VivoBook_ASUSLaptop X521EQ_S533EQ notebooks) and NVMe detection issues (Asus S533EA, HP AIO 24 DF1301NG, Acer Enduro EUN314-51WG, HP Pavilion laptop 15-eg0xxx/87CB).
  • ALBUS-8240, ALBUS-8409 - The feature ALBUS-8496 allows processing remote machines via Workflows and eliminate the situations where the remote process is blocked.
  • ALBUS-8520, ALBUS-8505 - When updating custom fields (loose drive processing), the custom field dialog box indicates what drive IDs are updated.
  • ALBUS-8251 - Some AMD and Nvidia graphics cards were not well supported (UI flickering).
  • ALBUS-8291 - The 7.1.0 image size has been reduced compared to the 7.0.0.
  • ALBUS-8699, ALBUS-8509, ALBUS-8591, ALBUS-8256, ALBUS-8656 - Several fixes related to the software stability.
  • ALBUS-7593 - Using an invalid XML path resulted in a Condition continuing via the red exit, which was confusing.
  • ALBUS-8549 - Fixing a problem where some NVMes would mark "Blancco SSD Erasure" as "Not Supported".
  • ALBUS-8552, ALBUS-8399 - Fixing a problem where drives connected to a LSI MegaRAID SAS 9266-8i or LSI MegaRAID SAS 9271-8i controller were failing the erasure.
  • ALBUS-8553 - Fixing a problem where Seagate Exos14 drives connected to LSI controllers (LSISAS2008 chip) were failing the erasure.
  • ALBUS-8541 - Fix for a problem with the Battery Discharge Test when run via a Workflow.
  • ALBUS-8547 - Fixing several issues with network booting on Dell machines (5289, 5490, 7390).
  • ALBUS-8317 - Fixing a delay existing between the end of an erasure and the sending of the report.
  • ALBUS-8209 - Fix for a problem where the Battery Discharge Test could be executed on a machine without a battery.
  • ALBUS-7822 - Fix for a problem where the screensaver progress bar jumped back and forth on occasions.
  • ALBUS-8393 - If no common/global custom field was defined, the Custom Field-step was visible but empty.
  • ALBUS-8388 - The Keyboard Test did not change the color of its background when a key was pressed.
  • ALBUS-8336 - Fix for a problem where a Computer-level Workflow would not start on a machine without any connected/detected drive.
  • ALBUS-8288 - Fix for a problem on the Server Message-action where variables could not be used to substitute a URL.
  • ALBUS-8489, ALBUS-8294, ALBUS-8412, ALBUS-8419, ALBUS-8206, ALBUS-8407, ALBUS-8175, ALBUS-7636, ALBUS-8567, ALBUS-8250 - Several fixes on the user interface.
  • ALBUS-8319 - Removing dummy network adapter information sent during communication with BMC.
  • ALBUS-8268, ALBUS-8387 - Some fixes related to the Optical drive test.
  • ALBUS-8748 - BDE 7 screensaver face-lift.
  • ALBUS-8381 - Fix for a problem with the "Report per drive" mode where N drives detected would save N issue reports.
  • ALBUST-880 - Image configuration: if the Erasure Process is set to "Workflow", custom fields can still be created but cannot be mandatory.
  • ALBUST-751 - Image configuration: custom fields with empty titles or custom fields with the same title are not allowed.
  • ALBUST-869 - Image configuration: fix for a problem where the folder name (and path) where the BDE images are located could not contain any special character.
  • ALBUST-876 - Image configuration: fix for a problem where Enterprise Edition images had some settings not available / greyed out.
  • ALBUST-785, ALBUST-786 - Image configuration: adding a progress indication when loading and saving images.
  • ALBUST-814 - Image configuration: fixing a problem where the image was marked as successfully saved when in reality it was not.
  • ALBUST-835 - Image configuration: most CT 3.0 sliders have been replaced with input text boxes.
  • ALBUST-848 - Image configuration: configuring the Erasure Process as "Workflow" only allows enabling automatic Hardware Tests.
  • ALBUST-817, ALBUST-867 - Image configuration: improvements on the Windows installer.
  • ALBUST-899, ALBUST-868 - Image configuration: fixing some issues with the configuration of thresholds.